Ki jan yo kreye yon orè antretyen prediksyon pou aparèy chofaj PFA ki baze sou sik tèmik kimilatif anrejistre yo?
Kite yon mesaj
Chofaj PFA yo echwe sitou nan mekanis fatig--tèmik estrès monte bisiklèt, ranpe, estrès anviwònman fann--pa mete inifòm. Pi bon prediksyon lavi aparèy chofaj la se kantite total sik tèmik (yon chanjman tanperati $\\ge 30^\\circ$C soti nan limen pou ale nan koupe oswa soti nan pakèt nan pakèt) e sa a pi bon pase tan kalandriye oswa èdtan total kouri. Sik medyàn yo echèk pou yon aparèy chofaj PFA sèvis endistriyèl komen (2 mm miray, 4 W/cm2, 80 degre likid) se 8,000-12,000 sik. Yon aksyon enspeksyon oswa ranplasman ka deklanche nan papòt sik predefini lè l sèvi avèk yon faktè konsomasyon lavi ki baze sou sik pou konstwi yon pwogram antretyen prediksyon epi sik kimilatif ka anrejistre. Anplis diminye ranplasman twò bonè, metòd sa a tou diminye echèk ki pa pwograme yo pa 60-80% konpare ak pwogram ki baze sou kalandriye.
Apwòch konte sik
Yon sik tèmik defini kòm yon chanjman nan tanperati a 30 degre oswa plis nan sifas la nan aparèy chofaj la nan pwen ki pi cho (souvan 10-20 cm pi wo pase fen frèt la). Nan ka aparèy chofaj ki manke nan detèktè tanperati -situ, yo ka itilize kontwolè pwosesis la pou kondui sik la: chak fwa aparèy chofaj la kouran apre li te etenn pou plis pase 30 minit (djenn lan ap refwadi a tou pre -anbyen) konte yon sik. Pou pwosedi pakèt kote tank la konplètman refwadi ant pakèt kouri, chak pakèt se yon sik. Konte sik pou chak evènman netwayaj pou pwosesis kontinyèl ak tanperati konstan men netwayaj chak jou (CIP) ki refwadi tank la. Pou pwosesis ki gen chofaj tanzantan (egzanp setpoint ak isterèz) sèlman konte sik lè tanperati a tranpe plis pase 15 degre pi ba pase setpoint, konsa chanjman modès (5-10 degre) pa konsidere kòm sik antye.
Sik anrejistreman yo ka fè pa fil elektrik yon kontwa elektwomekanik debaz (relè totalize) nan kontakè aparèy chofaj la. Si kontakè a louvri pou plis pase 30 minit, kontwa an ogmante lè li fèmen. Metòd pi konplèks yo itilize yon PLC oswa yon sistèm anrejistreman done pou konekte tanperati ak elektrisite. Konte sik la ta dwe estoke nan memwa ki pa-temèt epi sèlman reset lè yo ranplase aparèy chofaj la. Nan enstalasyon ki gen plis pase yon aparèy chofaj, chak aparèy chofaj ta dwe gen pwòp kontwa sik li yo (oswa yon idantifyan inik nan sistèm kontwòl la).
Faktè Sik Konsomasyon Lavi
But not all cycles are created equal. The Coffin-Manson fatigue relationship for PFA (damage ∝ ΔT^2.5–3.0) suggests that a cycle with ΔT=100°C (e.g. 20°C to 120°C) causes 8–10× greater fatigue damage than a cycle with ΔT=30°C (e.g. 50°C to 80°C). Low watt density heating cycles are less damaging than high watt density (>4 W/cm^2) chofaj cycles. Si aparèy chofaj la sèk (ekspoze ak lè) pou yon pati nan sik la, sa lakòz gwo domaj. Se poutèt sa, yon konte sik senp dwe pondere pa yon faktè severite. Sik domaj ekivalan (EDC)=sik aktyèl * (ΔTactual / ΔTref) n * (qactual / qref) m ΔTref=50 degre n=2.5 qref=3 W/cm2 m=1.5 Pou yon aparèy chofaj nan ΔT{{1} degre (faktè (80/50)^2.5=1.6^2.5 ≈ 4.0) ak q=4 W/cm2 (faktè (4/3)^1.5=1.33^1.5 ≈ 1.5), EDC=sik reyèl x 6.0 Pou menm aparèy chofaj ΔT {{2}cm2}, EDC {2}cm2}=sik aktyèl x (0.6)2.5 x (0.67)1.5=sik aktyèl x 0.22 x 0.55=sik aktyèl x 0.12.
Pou antretyen prediksyon efikas pifò enstalasyon yo anplwaye yon klasifikasyon senplifye severite:
Klas Severite ΔT pou chak Sik Watt Dansite (W/cm2) Severite Anviwònman Domaj Multiplier (parapò ak Modere) Egzanp tipik nan pwosesis
Modere 30 - 40 degre 2.5Clean likid, pa gen chòk tèmik 1.0× Chofaj dlo kontinyèl, tanperati fiks
Modere 40-60 degre 2.5-3.5Likid pwòp, monte bisiklèt dousman 2.5-3.5x Pakèt plating, sik chak jou
Grav 60-80 degre 3.5-5.0 Modere fouling, kèk chòk chalè 6-10× beny marinated, anpil chanjman pakèt
Extreme >80 °C or dry exposure >5.0 pwodwi chimik agresif, estrès tèmik, sik sèk 20-50 x asid tanperati ki wo ak pasè
Sik kimilatif Orè antretyen prediksyon
Severite Klas Sik pou Premye Enspeksyon (vizyèl, rezistans izolasyon) Sik pou Ranplasman Prevantif (80% nan lavi yo prevwa) Sik medyàn rive nan echèk prevwa Kalandriye Tan Ekivalan (1 sik/jou)
Modere 5,000 10,000 15,000 a 20,000 27 a 55 ane (souvan depase aparèy chofaj)
Modere 2,000 4,000 5,000–8,000 5–8 ane
Grav 800 1,500 2,000-3,500 2-5 ane
Ekstrèm 200-400 500-1,000 0.5-1.5 ane
Aplikasyon Orè Prediktif
Step 1: Fit cycle counters to all important heaters. For new installations provide heaters with a cycle counter built-in or supply a cycle counting relay in the control panel. It has to be power-loss resistant (either mechanical or battery-backed electrical). Step 2: Monitor both cycles and actual heater operation for the first 6 months. Insulation resistance testing should be carried out at 100 cycle intervals to establish a baseline link between cycles and degradation (a decline in insulation resistance from >1,000 MΩ a 100-500 MΩ endike kòmansman degradasyon grav). Etap 3: Kalite papòt ranplasman pou pwosesis sa a kont debaz la. Si pou egzanp rezistans izolasyon an desann a 200 MΩ nan 800 sik, mete ranplasman prevantif la nan 600 sik (75% nan kòmansman degradasyon an). Etap 4. Ekri konte sik la nan chak chanjman aparèy chofaj. Pran mwayèn aparèy chofaj plizyè, pou jwenn pi bon klasifikasyon klas severite pou pwosedi a.
Etablisman ki pa gen kontè sik yo ka rezonab estime konte sik yo lè yo miltipliye jou fonksyònman yo pa yon frekans sik yo espere. Si nou sipoze yon plant plating pakèt ak yon pakèt pou chak jou, sa a ta dwe 300 sik chak ane. Sipoze 50 sik/ane pou keu kontinyèl ak netwayaj chak semèn. Pou yon liy ak plizyè sik on/off pa jou (egzanp operasyon tanzantan) konte sik reyèl pou yon semèn, epi ekstrapolasyon. Erè a akòz apwoksimasyon an jeneralman +/- 30-50%. Sa a pi bon pase orè ki baze sou kalandriye (erè +/- 200% oswa plis) men pi mal pase aktyèl konte sik.
Estimate cycles from process logs for heaters in operation without cycle history. The log indicates the number of batches, cleaning cycles or power interruptions. Count 1 cycle every heating cycle (power on after >30 minit koupe). Miltipliye pa miltiplikatè severite ki nan tablo ki anwo a: Pou yon aparèy chofaj ki fonksyone pandan 3 ane ak 1 sik pa jou (1,095 sik) ak severite modere (miltiplikatè 3×), EDC=3,285. Chofaj la sou yon anviwònman modere epi yo ta dwe tcheke byento. Ranplase selon orè nan 3 mwa si sik ekivalan domaj yo pi gran pase nivo ranplasman prevantif la.
Konklizyon: Pwolonjman lavi ak evite echèk atravè sik-Orè ki baze sou
Yon kalandriye ki baze sou orè antretyen prediksyon ki baze sou sik tèmik kimilatif diminye echèk aparèy chofaj PFA ki pa pwograme a 60-80% ak ranplasman twò bonè nan 30-50%. Mete rle totalize debaz (kontè sik) sou chak aparèy chofaj, detèmine severite pwosesis (modere, modere, grav, ekstrèm) epi aplike limit sik pou enspeksyon (nan 50-70% nan lavi espere) ak ranplasman prevantif (nan 80% nan lavi espere). Si ou gen anpil aparèy chofaj pou yon pwosesis, swiv sik yo separeman. Aparèy chofaj la sou miray tank la ka gen diferan sik pase aparèy chofaj ki sitiye nan direksyon sant tank la akòz diferans tanperati lokalize. Orè ajisteman apre premye echèk chofaj lè w konpare sik aktyèl yo ak echèk nan papòt yo atann. Nan sit kote echèk aparèy chofaj PFA yo te enprevizib, entwodiksyon konte sik anjeneral diminye tan ki gen rapò ak echèk pa 70-90% nan premye ane a. Pri a nan yon kontwa sik (50-150perheater) recoveredafterpreventingasingleunplannedfailure(50-150perheater)recoveredafterpreventingasingleunplannedfailure(500-5,000 nan D 'ak ranplasman). Sèvi ak kontè sik PLC sou pwosesis esansyèl epi fè yo otomatikman alam lè yo frape 80% nan papòt ranplasman an. Operatè memwa-tèmik sik pa bati tou dousman, ak tan kalandriye se yon ranplasan pòv. Konte sik yo. Sik yo pral enfòme w ki lè pou ranplase.